Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

High Frequency Modified Sine Wave Inverter

EP1100 Pro Series (1.2-2.4KVA)

Features:

  • Rated power: 1.2KVA to 2.4KVA
  • Simulated sine wave inverter
  • Double layers PCB board
  • Configurable input voltage ranges(90-280VAC/170-280VAC) via LCD setting
  • Display accumulated working time
  • 3 steps charging algorithm
  • Auto restart while AC recovery
  • Overload & short-circuit protection, Battery reverse polarity protection, Deep discharge protection
  • Advanced technology optimizes battery life
  • Body with light strip and backlight display
  • Automatic line-to-battery switchover
  • 80cm Battery cables 12AWG*2

Where to Buy?


Overview


chagc-1

Adjustable Current

Charge current 10/20A adjustable.


battery-1

Battery Protection

With battery reverse protection function (optional).


ledlcd-1

LCD+LED

With LCD+LED display.


ep1100-pro-1

LCD/LED Display Information

1. FAULT LED
2. INVERTER MODE LED
3. MAINS MODE LED
4. LCD DISPLAY
5. POWER ON/OFF
6. SET KEY
7. FLIP KEY
8. ENTER KEY


Figure 1 Back Panel Information

1. DC Input Connector (Battery Terminal)
2. AC Input
3. Output Receptacle(s)


ep1100-pro-2


Other Features

It is a cost effective, intelligent solar inverter which accept Solar & Utility input at the same time. The comprehensive LCD display offers user-configurable and easy-accessible button adjustment such as battery charging current, AC/solar charger priority and DC priority.When battery voltage low,it will automatically switch to AC grid to supply continuously power to the loads.

Inverter Connection

ep1100-pro

Package

ep11plus-3

Specification

MODELEP11-1200EP11-1800EP11-2400
Default Battery System Voltage12VDC12VDC24VDC
INVERTER OUTPUT
Rated Power1200VA/720W1800VA/1000W2400VA/1440W
WaveformModifided Sine-wave
Nominal Output Voltage RMS230V
Output Voltage Regulation+10/-18%
Output Frequency50Hz/60Hz +/-0.5 Hz
Inverter Efficiency(Peak)>80%
Line Mode Efficiency>95%
Power Factor0.6
Typical Transfer TimeTypical 15~20ms 40ms max
AC INPUT
Voltage230VAC
Selectable Voltage Range—Narrow170~280VAC
Selectable Voltage Range—Wide90~280VAC
Frequency Range50Hz/60Hz (Auto sensing)
BATTERY
Nominal Input Voltage12VDC24VDC
Minimum Start Voltage10.5VDC21.0VDC
Low Battery Alarm10.5VDC+/-0.3V21.0VDC+/-0.3V
Low Battery Cutoff10.0VDC+/-0.3V20.0VDC+/-0.3V
High Voltage Alarm16.0VDC+/-0.3V32.0VDC+/-0.3V
High Battery Voltage Recover15.0VDC+/-0.3V30.0VDC+/-0.3V
CHARGER
Charger Voltage (Vbat<12.5V)14.4VDC+/-0.4V28.8VDC+/-0.4V
Charger Voltage (Vbat>12.5V)13.7VDC+/-0.2V27.4VDC+/-0.2V
Charging Current 10A10A±2A
Charging Current 20A20A±2A
Overcharge Protection S.D.16VDC ±0.4A32VDC ±0.8A
BYPASS & PROTECTION
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)FUSE
Output Short Circuit ProtectionFUSE
Bypass Fuse Rating10A
Max Bypass Current10Amp
MECHANICAL SPECIFICATIONS
Dimensions (W*H*D)253*267*90mm
Net Weight (kg)2.32.5
Shipping Dimensions(W*H*D)319*328*123mm
Shipping Weight (kg)2.93.1
OTHER
Operation Temperature Range0°C to 40°C
Audible Noise60dB MAX
DisplayLED+LCD
Standard Warranty1 year
Loading(20GP/40GP/40HQ)1800pcs / 3600pcs / 4200pcs

Approximate Back-up Time Table

Power Rate(w)backup time(H) @1*100Ahbackup time(H) @2*100Ahbackup time(H) @4*100Ahbackup time(H) @4*200Ah
7201.42.85.611.2
10000.91.93.87.5
1400 1.42.85.6
*required

*required

*required

*required

Related Products