Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

Low Frequnecy Pure Sine Wave Split Phase Inverter Charger

EP3300 TLV Series Split phase (1-6KW)

Features:

  • Pure sine wave output, split phase HOT1+ N + HOT2 available
  • Friendly user interface
  • 3 Steps charging
  • MFD (multi-function display)
  • Overload and short-circuit protection
  • Set charging voltage/charging current
  • Battery low voltage shutdown point can be set to 10/10.5/11V
  • Power-save mode
  • Set utility priority/ Battery priority
  • Set utility input wide/narrow range
  • Inverter voltage can be set to 100V/110V/120V
  • Inverter frequency can be set to 50/60Hz
  • Set utility charging on/off switch

Where to Buy?



LCD/LED Display Information

1. Switch ON/OFF: POWER ON/OFF Switch
2. MENU
3. UP
4. DOWN
5. ENTER
6. AC LED
7. INV LED
8. FAULT
9. LCD


Figure 1 Back Panel Information

1. AC OUTPUT
2: 220V/230V/240V output port
2. AC OUTPUT1: 110V/115V/120V output port
3. AC INPUT
4.15AMAX JFCI Output 110V/115V/120V Socket, 15A MAX




LCD/LED Display Information

1. Battery -/+
2. REMOTE PORT
3. BTS
4. AGS
5. RS232
6. AC OUTPUT2 PROTECT: Output 220V/230V/240V breaker
7. AC OUTPUT1 PROTECT: Output 110V/115V/120V breaker
8. AC INPUT PROTECT: Input protect breaker


Other Features

This inverter is applicable to different markets demands, it matches different voltage AC 120V/240V, also can set output voltage, frequency, charging voltage, charging current, it’s available to work in split phase power environment.

ModelEP33-1012TLVEP33-1024TLVEP33-1512TLVEP33-1524TLVEP33-2012TLVEP33-2024TLVEP33-3024TLVEP33-3048TLVEP33-4024TLVEP33-4048TLVEP33-5048TLVEP33-6048TLV
Inverter Output
Rated power(W)1KW1.5KW2KW3KW4KW5KW6KW
Power Factor1
Wave formPure sine wave/ Same as input waveform (bypass mode)
Output voltage RMS100V/110V/120VAC(200V/220V/240VAC)±10%
Output frequency50HZ or 60HZ (±0.3HZ) (can be set)
Overload protectionBreaker + software protection
Output short circuitBreaker + software protection
Inverter efficiency(peak)>80%
Overload100%<Load<110% (alarm 5min then stop output and fault code 07); 110%<Load<125% (alarm 60s then stop output and fault code 07); Load>125% (alarm 10s then stop output and fault code 07)
Surge rating3000VA4500VA6000VA9000VA12000VA15000VA18000VA
Capable of starting electric motor1P1P1.5P1.5P2P3P
Battery
Battery voltage12VDC/24VDC24VDC/48VDC48VDC
Minimum start voltage11VDC/22VDC/44VDC
Low battery voltage cut off(low voltage fault code04)10/10.5/11V for 12V model(*2 for 24DVC / *4 for 48VDC)
Low battery voltage alarmAdd 0.5V/battery: (low battery alarm one second one time) (10/10.5/11V) + 0.5Vdc for 12V model(*2 for 24DVC / *4 for 48VDC)
High battery voltage alarmAdd +1V/battery: (high voltage one second one time/after 30s fault 03) (13.8-14.5V) + 1V for 12V model(*2 for 24DVC / *4 for 48VDC)
Save modeLoad≤40W(110V)/80W(220V)
AC Input Mode
Input waveformPure sine wave
Nominal input voltage220Vac / 230Vac / 240Vac
Max input voltage270Vac MAX
Input frequency50HZ/60HZ (auto sensing)
Efficiency(AC mode)>95% (load, full battery)
Transfer time AC TO DC15ms(max)
Transfer time DC TO AC15ms(max)
Charge Mode
Boost Voltage14.1V(Default) Range of adjustment 13.8-14.5V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V)
Float Voltage13.5V(default) Range of adjustment 13.5-13.7V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V)
12V30A45A60A
24V20A25A30A40A60A
48V20A30A35A40A
Min charge current 10A. change by every 5A.
Dimensions
Dimensions (W*H*D)277*196*466mm277*186*621mm
Ship Dimensions (W*H*D)376*306*592mm376*296*747mm
  • Brochure: EP3300 TLV Series Split phase (1-6KW) Download
*required

*required

*required

*required

Related Products