Line Interactive UPS

EW2000 Pro Series (500-1000W)

Features:

  • Rated power 500W to 1000W
  • Pure sine wave output
  • High Battery Charging Capacity
  • AC auto restart
  • Built-in AVR function
  • Overload and Short circuit protection
  • Battery reverse polarity protection (Optional)
  • Discharge protection
  • Fault alarms and State Warnings
  • Compact size, light weight & low noise
  • Support USB, RS232 (Optional) monitoring function with free CD
  • Rack version available

Get Pricing/Info


Overview


ledlcd-1

LED/LCD

LCD/LED option.


battery-1

Battery Protection

Overload and short circuit protection.


sine-1

Pure Sine Wave

Pure sine wave output.


EP2000-PR01

LCD/LED Display Information

1. POWER ON
2. POWER OFF
3. LCD
4. Bypass LED
5. AC input LED
6. Battery LED
7. AC output LED
8. Fault LED
9. ESC
10. SEL
11. ENTER


Figure 1 Back Panel Information

12. RS232
13. Fax/Tel
14. USB
15. Fan
16. AC input
17. AC output
18. Battery input


EP2000-PR02



ew200-1

EW2000 PRO Inverter advantages

Rated Power: 750VA, 1KVA, 1.5KVA, 2KVA, 3KVA, 5KVA
* Pure sine wave output
* Built in AVR
* Auto restart while AC input
* user-friendly LED indicators and LCD display, showing battery voltage, and load power percentage.

AC INPUT: indicates greenwhen grid is normal, the light will be always on.
BATTERY: indicates yellowwhen the battery voltage is normal, the light will be always on
BYPASS: indicates yellowwhen the output of the bypass is normal, the light will be always on
AC OUTPUT: indicates greenwhen the output is normal, the light will be always on
 FAULT: indicates redThe light will be always on when there is fault and will flash when alarms



ew200-2


Battery power display


ew200-3
Discharge power display/Charging power display

Load power percentage


image031


USB or RS232

* Intelligent HMI function (human machine interface)
* Multiple setting functions: output frequency, charging current, average charging voltage, floating charging voltage, battery under-voltage turn-off point , buzzer on/off.
* Multiple protection function: over-voltage & under-voltage for battery, over-voltage & under-voltage for AC, over-frequency & under-frequency for AC, over-current output, short-circuit, over-temperature protection.


ew200-4


ew200-5


Battery


ew200-6
with inside battery: 2*9Ah


ew200-7
without inside battery: 12V for 750VA, 1KVA, 1.5KVA; 24V for 2KVA, 3KVA, 5KVA


Inverter Connection

It is a cost effective, intelligent inverter with UPS function. The comprehensive LCD offers user-configurable and easy-accessible button adjustment such as battery charge current, battery charge voltage, frequency, buzzer etc.

EP2000-PR03

↓↓↓Installation Portfolio------------

MUSTENERGY

Specification

ModelEW20-750VA ProEW20-1000VA ProEW20-1500VA Pro
Default Battery System Voltage12VDC24VDC
OUTPUT
Rated Power500W700W1000W
Power Factor0.7
WaveformPure Sine Wave
Output Voltage RegulationInverter Mode:230VAC(+/-2% RMS), AVR mode:195VAC-240VAC
Output Frequency5OHz/60Hz +/-0.2 Hz
Inverter Efficiency(Peak)>80%
Line Mode Efficiency>95%
Trasnfer TimeTypical 6ms 10ms(max)
AC INPUT
Input Voltage Regulation220/230/240VAC
Input Voltage Range140~275VAC+/-2%
Low Voltage Transfer Point:140VAC+/-2%
Low Voltage Recover Point:150VAC+/-2%
High Voltage Transfer Point:280VAC+/-2%
High Voltage Recover Point:270VAC+/-2%
Low Frequency Transfer Point:45+/-0.2HZ
Low Frequency Recover Point:46+/-0.2HZ
High Frequency Transfer Point:65+/-0.2HZ
High Frequency Recover Point:64+/-0.2HZ
Frequency Range50HZ/60HZ +/-0.2HZ
Auto Start>130VAC
BATTERY INPUT
Battery Low Voltage Alarming Point11.0VDC22.0VDC
Battery Low Voltage Shut-down Point10.5VDC11.0VDC
Battery High Voltage Shut-down Point15.4VDC30.8VDC
Battery Type&Number12V 9AH*112V 7AH*212V 9AH*2
Static Leakage Current<5mA
Charging Currrent2A
Backup Time>2minitues(50% load)
BYPASS & PROTECTION
WaveformsPure Sine Wave
Frequency50Hz or 60Hz
Overload Protection110%~125% R Load fault after 30S; 125% ~150%R Load  Fault after 3s >; 150%R Load Fault after 500ms
Other protectionsOvertemperature Protection,Bypass Output Protection,Battery Low Voltage Alarming, Battery Low Voltage Protection, Battery High Voltage Protection
Bypass Breaker Rating10A
Max Bypass Current10A
MECHANICAL SPECIFICATION
Dimensions405*145*210mm
Net Weight(kg)14KG18KG18.5KG
Cartons Dimension(W*H*D)480*290*225mm
Gross Weight (kg)15KG19KG19.5KG
Operation Temperature0°C~40°C 0~90% relative humidity (non-condensing)
OTHER
Temperature-15°C to 55°C
Altitude≦1000M
Nosie≦55dB
DisplayLED+LCD
CoolingAir Cooling
Fan starts>45℃fan start,<30℃ fan stop
Commication PortRS232 or USB

    *required

    *required

    *required

    *required

    Related Products