Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

Low Frequency Off Grid Solar Inverter

PV3000 MPK Series (1-6KW)

Features:

  • Rated power 1KW to 6KW
  • Pure sine wave output
  • Powerful charge rate up to 70Amp
  • Built-in MPPT solar charge controller 40A/60A
  • MPPT efficiency max 98%
  • Built-in pure copper UI transformer
  • DIP Switch offer customized performance
  • High Efficiency Design & “Power Saving Mode” to Conserve Energy
  • Supporting RS232 communication, AGS, BTS port
  • Remote control panel (optional)
  • Compatible to generator

Three Colors Option:

Red

Silver

Green

Where to Buy?


Overview


offgrid-1

Home Solar Power Inverter

1-6KW Off grid solar inverter for Home Power System.


chagc-1

MPPT Solar Charge Controller

Inbuilt with 40A or 60A MPPT solar charge controller.


sine-1

Pure Sine Wave

Pure sine wave output.


pv3000mpkbb-1

LCD/LED Display Information

1. AC Charge normal
2. AC power normal
3. Inverter normal
4. Check inverter
5. Charge current adjustable:25%,50%,75%,100%. (Optional)
6. PV voltage normal
7. Battery voltage normal
8. PV Charge normal
9. Battery type selector
10. LCD display

11. SwitchPower saver auto: Power on with saver mode(power saver ≤ 25W)
Unit Off: Power totally off(If there is AC power,inverter have charger function)
Power saver off: Power on without saver mode


Figure 1 Back Panel Information

12. Remote port
13. Function Switch(SW1~SW5)
14. BAT “-“
15. FAN
16. BTS
17. AGS
18. RS232 communication port
19. BAT “+”


pv3000mpkbb-2



pv3000mpkbb-3

Figure 2 Back Panel Information

20. AC input/Bypass breaker
21. AC output breaker
22. GND
23. PV input
24. AC input
25. AC output


Solar System Connection

This is a multi-function inverter ,combining functions of inverter and mppt solar charger controller, solar charger and battery charger to offer uninterruptible power support with portable size. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.

pv300mpk

Specification

MODELPV30-1KW MPKPV30-1.5KW MPKPV30-2KW MPKPV30-3KW MPKPV30-4KW MPKPV30-5KW MPKPV30-6KW MPK
Default Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC12VDC24VDC24VDC/48VDC24VDC/48VDC24VDC/48VDC
INVERTER OUTPUT
Rated Power1KW1.5KW2KW3KW4KW5KW6KW
Surge Rating (20ms)3KW4.5KW6KW9KW12KW15KW18KW
Capable Of Starting Electric Motor1HP1HP1HP2HP2HP3HP3HP
WaveformPure sine wave/ same as input (bypass mode)Pure sine wave/ same as input (bypass mode)
Nominal Output Voltage RMS100V/110V/120VAC 220V/230V/240VAC(+/-10% RMS)100V/110V/120VAC 220V/230V/240VAC220V/230V/240VAC
Output Frequency50Hz/60Hz +/-0.3 Hz50Hz/60Hz +/-0.3 Hz
Inverter Efficiency(Peak)>88%>88%
Line Mode Efficiency>95%>95%
Power Factor0.81.0
Typical Transfer Time10ms(max)10ms(max)
AC INPUT
Voltage120VAC/230VAC230VAC
Selectable Voltage Range96~132VAC 155~280VAC(For Personal Computers)96~132VAC/155~280VAC(For Personal Computers)
Frequency Range50Hz/60Hz (Auto sensing) 40-80Hz50HZ/60HZ (Auto sensing) 40-80Hz
BATTERY
Minimum Start Voltage10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, )20.0VDC~21.0VDC /40.0VDC~42.0VDC
Low Battery Alarm10.5VDC +/-0.3V for12VDC mode (*2 for 24VDC, )21.0VDC+/-0.6V /42.0VDC+/-1.2V
Low Battery Cutoff10.0VDC +/-0.3V for12VDC mode (*2 for 24VDC, )20.0VDC+/-0.6V /40.0VDC+/-1.2V
High Voltage Alarm16.0VDC +/-0.3V for12VDC mode (*2 for 24VDC, )32.0VDC+/-0.6V /64.0VDC+/-1.2V
High Battery Voltage Recover15.5VDC +/-0.3V for12VDC mode (*2 for 24VDC, )31.0VDC+/-0.6V / 62.0VDC+/-1.2V
Idle Consumption-Search Mode<25W when power saver on<50W when power saver on
AC CHARGER
Output VoltageDepends on battery typeDepends on battery type
Charger AC Input Breaker Rating10A30A30A30A40A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC, )31.4VDC/62.8VDC
Maximum Charge Current35A20A45A25A65A35A75A45A65A35A70A40A75A50A
BYPASS & PROTECTION
Input Voltage WaveformSine wave (grid or generator)Sine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breakerCircuit breaker
Output Short Circuit ProtectionCircuit breakerCircuit breaker
Bypass Breaker Rating10A15A30A30A40A
Max Bypass Current30Amp40Amp
SOLAR CHARGER
Maximum PV Array Power600W1200W600W1200W600W1200W600W1200W1600W3200W1600W3200W1600W3200W
Maximum PV Charge Current40A60A
DC Voltage12V/24V atuo work24V/48V atuo work
MPPT Range @ Operating Voltage16~100VDC32~145VDC @ 24V / 64~145VDC @ 48V
Maximum PV Array Open Circuit Voltage100VDC145VDC
Maximum Efficiency>90%>98%
Standby Power Consumption<2W<2W
MECHANICAL SPECIFICATIONS
MountingWall mountWall mount
Dimensions (W*H*D)423*247*197mm597x247x197mm
Net Weight (Solar CHG) kg18.32223.523282739.648.648.6
Shipping Dimensions(W*H*D)554*372*312mm743*372*312mm
Shipping Weight (Solar CHG) kg21.924.826.525.6313043.35353
OTHER
Operation Temperature Range0°C to 40°C
Storage Temperature-15°C to 60°C
Audible Noise60dB MAX
DisplayLED+LCD
Loading(20GP/40GP/40HQ)460pcs / 920pcs / 1060pcs320pcs / 640pcs / 750pcs

Approximate Back-up Time Table

Power Rate(w) backup time(H) @1*100Ahbackup time(H) @2*100Ahbackup time(H) @4*100Ahbackup time(H) @4*200Ahbackup time(H) @8*200Ah
1000 0.48061.6023.503047.6896 
2000 0.21360.48061.6023.503047.6896
3000 0.10680.28480.85442.1364.8416
4000 0.21360.48061.6023.50304
5000 0.128160.341761.196162.73408
6000 0.10680.28480.85442.136
  • Brochure: PV3000MPK.pdf Download
  • User Manual: 420-00245-01-PV3000-MPK.pdf Download
  • Certificates: PV3000-12V-TEST-REPORT-IEC60950-1-ES101214112S-4.pdf Download
  • Certificates: PV3000-24V-TEST-REPORT-IEC60950-1-ES101214113S-4.pdf Download
  • Certificates: PV3000-48V-TEST-REPORT-IEC60950-1-ES101214114S-4.pdf Download
  • Software: RS232-Watchpower.zip Download
*required

*required

*required

*required

Related Products

MUST Power The World! Contact Now