Description
■ Lithium Battery Modular 5120Wh/10240Wh/15360Wh
■ Self-consumption and feed-back to the grid
■ Multiple Working Mode: Energy storage mode, load priority mode, power selling mode,and a high-efficiency mode (six time periods are provided for setting different modes to achieve peak-shaving and valley-filling, maximizing economic benefits)
■ Inside BMS,support to be charged and discharged according to bms requirements
■ Support to connect with generator
■ Automatic line-to-battery switch over

| MODEL | HBP11-3648 LV | HBP11-4048 LV | |||
| Rated power | 3600W | 4000W | |||
| Nominal Battery System Voltage | 48V | ||||
| PV INPUT(DC) | |||||
| Maximum recommended DC power | 4000W | 5000W | |||
| Nominal DC operating voltage | 360V | ||||
| Maximum DC voltage | 500V | ||||
| MPPT voltage range | 120V~500V | ||||
| Maximum input current | 15A / 15A | ||||
| No.of MPP tracker | 2 | ||||
| Strings per MPP tracker | 1 | ||||
| INVERTER OUTPUT(AC) | |||||
| Nominal AC output power | 3600W | 4000W | |||
| Nominal output voltage; range | 110/120/130V; 90~140V | ||||
| AC grid frequency; range | 50/60Hz; 45~55/55-65Hz | ||||
| Nominal output current | 30A | 34A | |||
| Maximum output current | 33A | 36A | |||
| Inrush current (spike/duration) | 72A/5.2us | ||||
| Total harmonic distortion i(THDi) | <3% | ||||
| Power factor at rated power | 1 | ||||
| Displacement power factor | 0.8leading~0.8lagging | ||||
| Grid type | Single phase | ||||
| BATTERY MODE OUTPUT(AC) | |||||
| Output Rated Power | 3600W | 4000W | |||
| Nominal output voltage; accuracy range | 120±1% | ||||
| Output ferequency; accuracy range | 50/60Hz (optional)±0.2% | ||||
| Output rated current | 30A | 34A | |||
| Output waveform | Pure sine wave | ||||
| Peak power | 5400W,10s | 6000W,10s | |||
| Total harmonic distortion (linear load) | <3% | ||||
| BATTERY & CHARGER | |||||
| Note: Below Parameters base on one LiFePO4 Lithium Battery Modular | |||||
| Battery parameter | 51.2VDC 100Ah | ||||
| Number of battery pack | 1 | 2 | 2 | 3 | |
| Capacity | 5120Wh | 10240Wh | 10240Wh | 15360Wh | |
| Charging curve | 3-stage adaptive with maintenance | ||||
| Protection | Over-current protection / Over-temperature protection | ||||
| Maximum charging power | 3600W | 4000W | |||
| Maximum charging currernt | 75A | 85A | |||
| EFFICIENCY | |||||
| Maximum efficiency | 97.1% | ||||
| Euro-efficiency | 96.5% | ||||
| MPPT efficiency | 99.8% | ||||
| PROTECTION DEVICES | |||||
| DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring; Integrated all-pole sensitive leakage current | |||||
| MECHANICAL SPECIFICATIONS | |||||
| Machine Dimension (W*H*D)(mm) (Inverter+Battery) | 594*1154*220(5120Wh); 594*1559*220 (10240Wh); 594*1964*220 (15360Wh) | ||||
| Package Dimension (W*H*D)(mm) | Inverter | 900*335*714 | |||
| Battery | 666*280*483 (Single Battery) | ||||
| N.W(kg) | Inverter | 42 | |||
| Battery(51.2V100Ah) | 52 | ||||
| G.W(kg) | Inverter | 55 | |||
| Battery(51.2V100Ah) | 57 | ||||
| Standard Warranty | Inverter: 5 years ; Lithium battery: 5 years | ||||
| OTHER | |||||
| Operating Temperature Range | -15°C to 40°C | ||||
| Ingress protection rating | IP66 | ||||
| Audible Noise | 60dB MAX | ||||
| Display | LED+LCD | ||||
| CERTIFICATION & STANDARDS | |||||
| CE-EMC | |||||