Online UPS EH5500 (1/3kW)

The EH5500 series is a new type high-frequency online UPS. Adopts advanced DSP digital control technology to effectively improve product performance and system reliability, and higher power density small size, light weight and high work efficiency. Effectively solve power problems such as power cut-off, Grid over voltage/low voltage, voltage instantaneous drop, amplitude reduction, high voltage pulse, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and provide best power for load.

Category:
Description

Description

■ With double conversion online design, zero output transfer time.
■ Adopt DSP digital control
■ Adopt the technology of active power factor correction technology (PFC)
■ With LCD+LED real-time display
■ With 3-5 minutes can work when on full loads.
■ Cold start by battery without grid Input.
■ Input frequency range 40~70Hz

MODEL EH55-H1K2 EH55-H1K3 EH55-H3K6 EH55-H3K8
Rated Capacity 1KVA/1KW 3KVA/3KW
INPUT
Input format L+N+PE
Rated input voltage 208/220/230/240VAC
Voltage range 110~300VAC
Frequency range 50/60±6Hz (Default), ±10Hz (Settable)
Input power factor ≥0.99
Input total harmonic distortion ≤4% linear load
OUTPUT
AC Output Port 3
Output format L+N+PE
Output voltage 208/220/230/240VAC
Output accuracy ±1%
Output frequency For on-line mode: follow current frequency, battery mode: 50/60Hz±0.1%
Output harmonic distortion ≤ 2% linear load; ≤ 4% nonlinear load (PF=0.7)
PF 1
Overload capacity AC mode 30min@102%~110% Load; 10min@110%~130% Load; 30s@130%~150% Load; 200ms@>150% Load
Batterymode 10min@102%~110% Load; 1min@110%~130% Load; 10s@130%~150% Load; 200ms@>150% Load
SWITCHING TIME
Switch to battery mode 0ms
Switch to bypass 4ms
AC priority mode Support
EFFICIENCY
AC Mode (Full Load) 94.5%@220VAC 95.5%@220VAC
Battery Mode for without built-in battery (Full Load) 88.5%@36VDC 91.5%@96VDC
Battery Mode for withbuilt-in battery (Full Load) 87.5%@24VDC 91.5%@72VDC
BATTERY
Battery type Lead Acid Battery
Rated Battery Voltage 24V 36V 72V 96V
Battery Spec 2*12V/9Ah 3*12V/7Ah 6*12V/9Ah 8*12V/7Ah
Number of InternalBattery 2/3(optional) 6/8(optional)
Chaging current Built-in battery 1K-3K: 1A (Default) 1-2A (Adjustable) Without built-in battery 1KS-3KS: 5A (Default) 1-12A (Adjustable)
Charging mode Two-stage/three-stage charging
DISPLAY
LCD 2×8PIN/Pitch2.54mm, support 128-bit segment code, up to 4 buttons + 4 LEDs, can display operating mode / load / input / output, etc.
INTERFACE
RS-232 Support: Windwos 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC
USB Windows Famlly & MAC
Intelligent slot(Optional) SNMP/AS400 Relay Card/RS485
EPO (Optional) Support
ENVIRONMENTAL PARAMETERS
Operating ambient temperature 0~40°C
Operating environment humidity 20%~95% (no condensation)
Storage temperature -15~60°C (batteries: 0~40°C )
Altitude The elevation should not exceed 1000m, 1000m or above, up to 4000 m, reference IEC62040
Noise ≤45db
MECHANICAL SPECIFICATIONS
Machine Dimension(W*H*D)(mm) 143*222*285 143*222*354 192*326*397
Package Dimension(W*H*D)(mm) 235*320*380 235*320*448 312*452*527
N.W (kg) 7.5 10 20 24
G.W (kg) 8.5 11 21.5 25.5
Standard Warranty 1years