Description
Features:
■ LCD display , easy to operate on LCD screen
■ Multi stage charging (3-stage charging , parallel charging and equalized charging function)
■ Maximum Solar Input Voltage: 245V
■ BTS – Battery remote temperature sensor terminal
■ Enable to charge Li-thium, Gel , lead-acid battery
■ With RS485 & USB communication port
■ Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit

| MODEL | PC18-6025F | PC18-8025F | PC18-10025F | ||
| Nominal Battery System Voltage | 12V / 24V / 48VDC (Auto detection); 36V (Setting) | ||||
| CONTROLLER INPUT | |||||
| Battery Voltage | 12V / 24V / 36V / 48V | ||||
| Maximum Solar Input Voltage | 12V (VBAT) | 100V | |||
| 24V (VBAT) | 245V | ||||
| 36V (VBAT) | 245V | ||||
| 48V (VBAT) | 245V | ||||
| PV Array MPPT Voltage Range | 12V (VBAT) | 15-95V | |||
| 24V (VBAT) | 30~230V | ||||
| 36V (VBAT) | 45~230V | ||||
| 48V (VBAT) | 60~230V | ||||
| Maximum Input Power | 12V (VBAT) | 940W | 1250W | 1560W | |
| 24V (VBAT) | 1880W | 2500W | 3120W | ||
| 36V (VBAT) | 2820W | 3750W | 4680W | ||
| 48V (VBAT) | 3760W | 5000W | 6250W | ||
| BATTERY | |||||
| Charging Set Points | Flooded Battery | Absorption Stage | 14.2V / 28.4V / 42.6V / 56.8V | ||
| Float Stage | 13.7V / 27.4V / 41.1V / 54.8V | ||||
| AGM (Default) |
Absorption Stage | 14.4V / 28.8V / 43.2V / 57.6V | |||
| Float Stage | 13.7V / 27.4V / 41.1V / 54.8V | ||||
| Over-charging Voltage | 15.5V / 30.0V / 45.0V / 60.0V | ||||
| Over-charging Comeback Voltage | 14.5V / 29.5V / 44.5V / 59.0V | ||||
| Battery Defect Voltage | 10.0V / 17.0V / 25.5V / 34.0V | ||||
| Temperature Compensation Conefficient | -5mv / °C /cell (25°C vef) | ||||
| Peak Conversion Efficiency | 98% (MPPT Efficiency 99%) | ||||
| Maximum Battery Current | 60A | 80A | 100A | ||
| Maximum DC load current | / | / | 100A | ||
| Max Charging Current | 60amps continuous @ 40°C ambient | 80amps continuous @ 40°C ambient | 100amps continuous @ 40°C ambient | ||
| DISPLAY & PROTECTION | |||||
| Protections | Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect | ||||
| MECHANICAL SPECIFICATIONS | |||||
| Machine Dimension (W*H*D)(mm) | 163.6*306.6*94.9 | 165*284*97 | |||
| Package Dimension (W*H*D)(mm) | / | / | |||
| N.W(kg) | 3 | 4 | |||
| G.W(kg) | / | / | |||
| OTHER | |||||
| Mounting | Wall mount | ||||
| Environmental Rating | Indoor | ||||
| Enclosure | IP20 | ||||
| Radiating Mode | Fan cooling | ||||
| Operating Temperature Range | -10~55°C | ||||
| Ambient Humidity | 0~90% relative humidity (non-condensing) | ||||
| Altiude | ≤3000m | ||||
| CERTIFICATION & STANDARDS | |||||
| UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010) CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010) |
|||||