Description
■ 3 Steps charging
■ MFD (multi-function display)
■ Overload and short-circuit protection
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority/ Battery priority
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 110V/115V/120V
■ Inverter frequency can be set to 50/60Hz
■ Set utility charging on/off switch
■ Acid or Lithium Select
■ WIFI monitoring function (optional)
■ With BMS lithium battery communication function (CAN port)

| MODEL | EP30-1012 LV2 | EP30-1024 LV2 | EP30-1512 LV2 | EP30-1524 LV2 | EP30-2012 LV2 | EP30-2024 LV2 | EP30-3024 LV2 | EP30-3048 LV2 | EP30-4024 LV2 | EP30-4048 LV2 | EP30-5048 LV2 | EP30-6048 LV2 |
| Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | 48VDC | 24VDC | 48VDC | 48VDC | 48VDC |
| INVERTER OUTPUT | ||||||||||||
| Reted Power | 1.0KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||
| Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | |||||
| Capable Of Starting Electric Motor | 1HP | 2HP | 3HP | |||||||||
| Waveform | Pure sine wave/ same as input (bypass mode) | |||||||||||
| Nominal Output Voltage RMS | 110V/115V/120VAC ±10% (RMS) | |||||||||||
| Output Frequency | 50Hz / 60Hz±0.3 Hz | |||||||||||
| Inverter Efficiency(Peak) | >88% | |||||||||||
| Line Mode Efficiency | >95% | |||||||||||
| Power Factor | 1.0 | |||||||||||
| Typical Transfer Time | 10ms(max) | |||||||||||
| Overload | 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07) | |||||||||||
| AC INPUT | ||||||||||||
| Voltage | 120VAC | |||||||||||
| Selectable Voltage Range | 75~135VAC(For Personal Computers) | |||||||||||
| Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||||||||||
| BATTERY | ||||||||||||
| Minimum Start Voltage | (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
| Low battery voltage alarm | (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
| Low battery voltage cut off | 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
| High battery voltage alarm | (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
| High battery voltage recover | (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
| Energy saving mode | Load ≤50±20W(120V) | |||||||||||
| CHARGER | ||||||||||||
| Output Voltage | Depends on battery type | |||||||||||
| Charger AC Input Breaker Rating | 1K/30A | 3K/40A | 4-6KW/63A | |||||||||
| Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) | |||||||||||
| Maximum Charge Current | 30A | 20A | 45A | 25A | 60A | 30A | 40A | 20A | 60A | 30A | 35A | 40A |
| BYPASS & PROTECTION | ||||||||||||
| Input Voltage Waveform | Sine wave (grid or generator) | |||||||||||
| Nominal Input Frequency | 50Hz or 60Hz | |||||||||||
| Overload Protection (SMPS Load) | Circuit breaker | |||||||||||
| Output Short Circuit Protection | Circuit breaker | |||||||||||
| AC Input Breaker | 30A | 40A | 50A / 63A | |||||||||
| MECHANICAL SPECIFICATIONS | ||||||||||||
| Mounting | Wall Mount | |||||||||||
| Machine Dimension (W*H*D)(mm) | 303*493*200 | 305*531*202 | ||||||||||
| Package Dimension (W*H*D)(mm) | 615*319*400 | 686*319*400 | ||||||||||
| N.W(kg) | / | |||||||||||
| G.W(kg) | / | |||||||||||
| OTHER | ||||||||||||
| Operation Temperature Range | 0°C to 40°C | |||||||||||
| Storage Temperature | -15°C to 60°C | |||||||||||
| Audible Noise | 60dB MAX | |||||||||||
| Display | LED+LCD | |||||||||||
| Standard Warranty | 2 year | |||||||||||