Description
■ Multiple operation modes: Grid-tie,off grid with storage backup
■ IP65 water-proof and dust-proof
■ MPPT voltage range 120-500V
■ Support LCD display&Smart LCD setting
■ Available Export control CT sensor function
■ Multiple communications:USB,RS485,GPRS and wifi etc
■ Full protection function:Over-voltage,over-frequency, over-current, over-temperature,and AC short-circuit automatic protection
■ Intelligent BMS battery management function
■ Fanless low-noise design
■ Wifi monitoring

| MODEL | PH11-3648 LV | PH11-4048 LV |
| Rated Power | 3600W | 4000W |
| Nominal Battery System Voltage | 48V | |
| PV INPUT(DC) | ||
| Maximum recommended DC power | 4600W | 5200W |
| Nominal DC operating voltage | 360V | |
| Maximum DC voltage | 500V | |
| MPPT voltage range | 120V~500V | |
| Maximum input current | 15A / 15A | |
| No.of MPP tracker | 2 | |
| Strings per MPP tracker | 1 | |
| INVERTER INPUT/ OUTPUT(AC) | ||
| Nominal AC input/ output power | 3600W | 4000W |
| Nominal input/ output voltage; range | 110/120/130V; 90~140V | |
| AC grid frequency; range | 50/60Hz; 45~55/55-65Hz | |
| Nominal input/ output current | 30A | 34A |
| Maximum input/ output current | 33A | 36A |
| Inrush current (spike/duration) | 72A/5.2us | |
| Total harmonic distortion i(THDi) | <3% | |
| Power factor at rated power | 1 | |
| Displacement power factor | 0.8leading ~ 0.8lagging | |
| Grid type | Single phase | |
| BATTERY MODE OUTPUT(AC) | ||
| Output Rated Power | 3600W | 4000W |
| Nominal output voltage; accuracy range | 120±1% | |
| Output ferequency; accuracy range | 50/60Hz (optional)±0.2% | |
| Output rated current | 30A | 34A |
| Output waveform | Pure sine wave | |
| Peak power | 5400W,10s | 6000W,10s |
| Total harmonic distortion v (linear load) | <3% | |
| BATTERY & CHARGER | ||
| Battery type | Lead-acid battery / Lithium battery | |
| Battery voltage | 48V | |
| Battery voltage range | 40~60V | |
| Charging curve | 3-stage adaptive with maintenance | |
| Protection | Over-current protection / Over-temperature protection | |
| Maximum charging power | 3600W | 4000W |
| Maximum charging currernt | 75A | 85A |
| EFFICIENCY | ||
| Maximum efficiency | 97.1% | |
| Euro-efficiency | 96.5% | |
| MPPT efficiency | 99.8% | |
| PROTECTION DEVICES | ||
| DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring; Integrated all-pole sensitive leakage current | ||
| MECHANICAL SPECIFICATIONS | ||
| Machine Dimension (W*H*D)(mm) | 420*480*215 | |
| Package Dimension (W*H*D)(mm) | 610*324*595 | |
| N.W(kg) | 30 | |
| G.W(kg) | 32 | |
| GENERAL | ||
| DC connection | H4 / MC4 | |
| AC connection | Terminal Block | |
| Display | LED+LCD | |
| Communication interfaces | Wi-Fi / USB / GPRS / RS485 | |
| Ingress protection rating | IP65 | |
| Humidity | 0~95% RH(No codensing) | |
| Operating temperature range | -20°C+60°C With derating above 45°C | |
| Cooling concept | Natural | |
| Altitude | <3000m | |
| Standard Warranty | 5years | |
| CERTIFICATION & STANDARDS | ||
| CE-EMC+LVD (EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011); CE-LVD(EN62477-1:2022) IEC60529; EN50549-1:2019; Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021), C10/C11; UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A); G98+G99 | ||