Description
■ 100% unbalanced output, each phase max. output up to 50% rated power
■ Max. 6 pcs parallel for on-grid and off-grid operation
■ AC couple to retrofit existing solar system
■ Support multiple batteries parallel
■ Max. charging/discharging current of 240A
■ Support storing energy from diesel generator
■ 48V low voltage battery, transformer isolation design
■ IP66 water-proof and dust-proof
■ “Time of use” function: a maximum of 6 time segments can be set
■ Wifi monitoring

| MODEL | PH11-5KL3-EU | PH11-6.5KL3-EU | PH11-8KL3-EU | PH11-10KL3-EU | PH11-12KL3-EU |
| Rated power | 5000W | 6500W | 8000W | 10000W | 12000W |
| BATTERY INPUT DATA | |||||
| Battery type | Lead-acid battery / Lithium battery | ||||
| Battery voltage | 48V | ||||
| Battery voltage range | 40~60V | ||||
| Charging curve | 3-stage adaptive with maintenance/Equalization | ||||
| Charging Strategy for Li-lon Battery | Self-adaption to BMS | ||||
| Over-current protection/ Over-temperature protection | Yes / Yes | ||||
| Maximum charging/discharging power | 5000W | 6500W | 8000W | 10000W | 12000W |
| Maximum charging/discharging current | 120A | 150A | 190A | 210A | 240A |
| PV STRING INPUT DATA | |||||
| Max. DC Input Power | 6500W | 8450W | 10400W | 13000W | 15600W |
| Rated PV Input Voltage | 550V | ||||
| Maximum DC voltage | 800V | ||||
| Start-up Voltage | 160V | ||||
| Minimum voltage for grid connection | 310V | ||||
| Full Load DC Voltage Range | 350-650V | ||||
| Enter high voltage error recovery point | 800V | ||||
| MPPT voltage range | 200~650V | ||||
| Maximum input current | 13A/13A | 13A+26A | |||
| No.of MPP Trackers | 2 | ||||
| No.of Strings per MPP Tracker | 1+1 | 2+1 | |||
| AC INPUT/OUTPUT DATA | |||||
| Rated AC Input/ Output Power | 5000W | 6500W | 8000W | 10000W | 12000W |
| Max AC Input/ Output Power | 5500W | 7150W | 8800W | 11000W | 13200W |
| AC Input/ Output Rated Current | 7.6/7.2A | 9.8/9.42A | 12.1/11.6A | 15.2/14.5A | 18.2/17.4A |
| Max AC Input/ Output Current | 8.4/8A | 10.8/10.4A | 13.4/12.8A | 16.7/15.9A | 20/19.1A |
| Max. Three-phase Unbalanced Output Current | 11.4/10.9A | 14.7/14.1A | 18.2/17.4A | 22.7/21.7A | 27.3/26.1A |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
| Rated Input/Output Voltage | 220/380,230/400Vac | ||||
| Rated Input/Output Grid Frequency/Range | 50/60;45~55/55-65 | ||||
| Grid Type | Three Phase | ||||
| Total Harmonics Current Distortion (THDi) | <3% (of nominal power) | ||||
| DC Current Injection | <0.5% In | ||||
| EFFICIENCY | |||||
| Max. Efficiency | ≥97.6% | ||||
| Euro Efficiency | 97.0% | ||||
| PROTECTION | |||||
| Integrated | Islanding protection, PV input polarity reverse protection, insulationresistance detection, surge protection,leakage current monitoringprotection,output current protection, output short circuit protectionoutput overvoltage protection | ||||
| Surge Protection | DC Type III/AC Type III | ||||
| Overvoltage Category | DC Type II/AC Type III | ||||
| GENERAL DATA | |||||
| Operating Temperature Range (°C) | -25°C to +60°C, >45°C Derating | ||||
| Cooling | Fan cooling | ||||
| Noise (dB) | ≤55dB | ||||
| Communication with BMS | RS485/CAN | ||||
| Machine Dimension (W*H*D)(mm) | 446*692*260 (excluding connectors and racks) | ||||
| Package Dimension (W*H*D)(mm) | 567*816*404 | ||||
| N.W(kg) | 38 | ||||
| G.W(kg) | 42 | ||||
| Protection Degree | IP66 | ||||
| Installation Style | Wall-mounted | ||||
| Warranty | 5 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
||||
| CERTIFICATION & STANDARDS | |||||
| CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC 62109-1, EN IEC 62109-2); CE-LVD(EN 62477-1) ; IEC 60529; EN50549-1; Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)C10/C11; UNE217001-2020; UNE217002-2020, NTS-631 (Type A); G98+G99 | |||||